Miniature multifunction meter for all kinds of DIY projects
Since meters make up a fairly large share of the products bought by radio amateurs, especially beginners, I hope this review will be more useful to them than to experienced folks.
People often send me all sorts of links, and I try things out whenever I can, so I’m always glad to hear about new products :)
Now, let’s get to the review.
The little meter arrived in a tiny box. At first I couldn’t even tell what it was; then I spotted the “33V 3A” marking on the box.
The package consisted of the meter with wires attached and an instruction manual.
The meter’s stated specifications are as follows:
Voltage measurement range: DC 0-33V
Current measurement range: 0-3A
Power measurement range: 0-99W
Energy measurement range: 0-999.9Wh
Voltage measurement accuracy: ±(0.3%+3digits)
Current measurement accuracy: ±(0.8%+3digits)
Capacity measurement accuracy: 0-99.999Ah
Time measurement accuracy: 0-99h59min
Temperature measurement accuracy: -15℃-60℃
Size: 46 x 29 x 17mm
Wire length: appro 140mm
After I received the meter and read the manual, I noticed there were two more interesting versions, for almost the same price. At least, those versions would have been more useful to me.
The manual is quite informative.
It shows several ways to connect the meter.
It also gives a full description of the specifications, though in English.
The meter’s dimensions match those of common panel voltmeters and ammeters, so it’s a direct replacement for the types currently in use.
I think that’s a big plus, since you can upgrade a meter’s functionality simply by replacing it. I think you could even just take the guts out of the old case and put the new ones in.
Overall view.
The meter came with connection wires. They’re of average quality, just like those supplied with all the other meters of this type—neither better nor worse.
There are two connectors on the circuit board.
The upper connector supplies power to the meter and also provides the voltage measurement input.
The lower connector is for current measurement.
There are no adjustment components; calibration is most likely entirely software-based, if it exists at all.
With a fairly gentle movement, the meter separates into two parts.
The clips are quite tight, though, and given how delicate the display is, I wouldn’t recommend taking it apart unless you really need to.
The other side of the circuit board has only the display and a control button.
The display is connected to the board with a fairly wide ribbon cable. Since the case is a standard size, the extra thickness is made up with a small piece of foam rubber.
This piece of rubber is what protects the display from damage: if it were mounted rigidly, it could easily break.
I have no particular complaints about the circuit board assembly; it’s fairly neat and clean. The temperature sensor is visible at the top (it would be much more convenient if it were on wires, too). I also noticed that a tantalum capacitor was used in the power supply circuit instead of an aluminum electrolytic one, which I think is an improvement.
A little about what’s inside the device.
1. The device uses a standard 25 mΩ SMD resistor as its current shunt.
The 10 A versions use a wire-wound shunt here; you can see the holes for soldering it in next to it.
Unfortunately, you can’t convert the device to the other version, since the operating mode is most likely hard-coded in the microcontroller.
2. The voltage across the shunt is fed to an LM358 op-amp. Not a great choice, since this op-amp doesn’t perform particularly well with very low voltages. They could have used something better :(
3. The op-amp output is fed to an 8s003f3p6 microcontroller. It’s a basic, inexpensive microcontroller with a 10-bit ADC, the kind used in most ammeters and voltmeters. Essentially, this device is a standard ammeter/voltmeter with extra features and a different type of display.
4. The whole circuit is powered by an M5336B linear voltage regulator. Reverse-polarity protection is provided by a 15 Ω resistor in series with the input and a diode connected in parallel with the regulator input. In other words, if the power is connected backwards, the resistor burns out, but the device survives.
Let’s turn it on.
Yes, the screen is small, and it displays a lot of information. At least they had the good sense to make the voltage and current readings larger.
That said, the display is quite bright and sharp.
Now, let’s see what’s shown on the display.
Left column:
Operating time in hours and minutes; resets when power is lost.
Power. Technically, this is just the measured voltage multiplied by the measured current.
Operating mode indicator. I’ll explain that a little later.
Temperature. Technically, it measures the temperature of the device. It would be much more useful to put the sensor somewhere else, and ideally add a fan control circuit.
Amp-hour counter.
Right column:
Measured voltage
Measured current
Watt-hour counter.
Now, about the operating modes.
There’s a button on the front panel. The manual makes it hard to figure out what it does, but it’s easy to understand by trying the device, so I’ll explain it in simpler terms.
The device has amp-hour and watt-hour counters, but there are actually two sets of them.
So, start the device in the first mode and it starts counting—for example, the capacity of the battery being charged. If you need to check the capacity of a second battery, press the button to switch to the second mode. It works the same way, but uses the second set of counters.
Charge the second battery. After that, you can press the button to view the results from the first and second measurements.
A long press resets the counters for the selected mode. In other words, whichever mode you hold the button in is the one whose counters will be reset.
I hope that was clear :) In a nutshell, it’s convenient.
First test.
We apply the voltage to be measured to the meter, then connect a light bulb as a load. The voltage dropped across the wires and connections, so you can ignore it in the second setup.
Now we can test it more properly.
First, I checked the voltage measurement accuracy. All the tests were done under the least favorable conditions, with the meter powered by the circuit being measured. That's why the maximum voltage was 20 V, as specified in the manual.
The stated maximum error was 0.3% + 3 counts. The meter easily stayed within the specified error, with plenty of room to spare, since the measured voltage differed by no more than the last 3 digits.
The meter reads slightly high, but even so, it's clear that it meets the stated specifications.
But when I checked the current measurement accuracy, I got a little “surprise.”
First, I connected the ends of the negative wires at a single point, but the test results were noticeably too high.
Then, just to experiment, I connected the load directly to the connector, so the load current didn't flow through the meter's wires; only the meter itself was powered.
And the results were noticeably better.
The first setup is on the left; the second, with the load connected directly to the connector, is on the right.
Since it's more accurate to measure the error at the maximum current, I'll calculate it for that value.
The specified error is 0.8% + 3 counts. At 3 A, that gives 3000 × 1.008 + 3 = 3,027, or 2,973 in the other direction.
So the meter is “within tolerance” if its reading differs from the actual value by no more than 27 counts.
With the first setup, the difference was 41 counts; with the second, 26 counts.
In other words, the meter was out of tolerance with the first setup, but still within tolerance with the second, albeit just barely. I think it could easily be adjusted if needed, but this level of accuracy is good enough for me.
Finally, I checked the operating limits.
First, I applied a current of 190 mA. The meter displayed 187 mA, which is excellent, since the difference was within the last 3 digits.
Then I decided to check the maximum current.
The meter still works normally at 3.2–3.3 A, but above that, dashes appear instead of the current reading.
The interesting thing is that the meter actually keeps measuring; you can see this from the power reading. Dividing the calculated power of 33.47 W by the input voltage of 9.73 V gives a current of 3.432 A, which is roughly the actual value. So the limit is probably just in the software.
That’s about it. Today’s review is very short, but I don’t think that made it much less informative.
Pros
Compact size
Same dimensions as standard ammeters/voltmeters
Two independent counters.
Acceptable measurement accuracy.
Temperature measurement
Versions with higher current are available.
Cons
Small display
A soldering iron is needed to move the temperature sensor outside the case
Current measurement accuracy depends on where the load is connected.
My take: this is definitely an interesting device. Despite its compact size, it lets you add functionality to existing devices without modifying them. As I mentioned in the testing section, there are issues with current measurement accuracy: the reading depends on where you connect the load. But I think the results would be better if the meter were powered separately from the circuits being measured. I also showed that everything reads correctly when the load is connected closer to the shunt.
I liked the nice little touch of having two independent Ah and Wh counters, but I was disappointed that the temperature sensor isn’t very convenient to move outside the case, and measuring the temperature of the meter’s case is pointless.
I’d really like to be able to control a fan using the same temperature sensor, but that feature isn’t available yet :(
That’s about it. I hope you found the review useful. As always, feel free to ask questions in the comments :)
The product was provided by the store for review.
пользование миниатюрной измерительной клипсой, cамодельный многофункциональный lcf измеритель, миниатюрный мутивольтметр, https://www.kirich.blog/P177, gl-d2394 универсальный миниатюрный, измеритель многофункциональный, проекты 8s003f3p6, 7890, 8s003f3p6, миниатюр универсальный, поделки из старого счетчика, миниатюрный многофункциональный мультиметр
Questions and answers
What does the 33 V, 3 A miniature meter measure?
It displays voltage, current, power, energy in Wh, capacity in Ah, operating time, and temperature.
Why does the meter’s current-reading accuracy depend on the load connection?
The author found that readings vary with the connection point; they return to normal when the load is connected closer to the shunt.
Can this meter replace a standard panel ammeter-voltmeter?
Its dimensions match those of common panel meters, so it can be used as a replacement. It also has two independent Ah and Wh counters.
This model is included in the summary table: Comparison of measuring instruments reviewed on the blog
The figures from this review are in the measurement database: Measuring instruments