/    Measurement database » Power supplies » HCA-100 or LS-100W-24V
Support the project on Patreon


Comparison · Power supplies

HCA-100 or LS-100W-24V

Two models side by side: measurements taken by the author in their reviews, and their conclusions. The better value in each row is highlighted.

In brief: Based on review measurements: Test current: HCA-100 (9 A vs. 5.4); Ripple: LS-100W-24V (60 mV vs. 200); Efficiency: HCA-100 (89 % vs. 87); Temperature rise: LS-100W-24V (76 °C vs. 110).

ModelHCA-100HCA-1002025Read review →LS-100W-24VLS-100W-24V2025Read review →
Current, A8.34.17
Power, W100100
Test current, A95.4
Ripple, mV20060
Efficiency, %8987
Protection, A95.4
Temperature rise, °C11076
Review conclusionRecommendedRecommended

HCA-100: High efficiency, low ripple and excellent voltage stability; recommended with practical output limited to 70–80 W.

LS-100W-24V: Excellent performance, with low ripple and plenty of thermal headroom even under modest overload.

Figures were taken from the review text and checked against the quoted passages. Measurement conditions differ between reviews, so read the reviews yourself before buying. Prices at the time of review.

Compare two modelsor

Similar comparisons

← All: power supplies