/    Measurement database » Power supplies » HCA-100L or MeanWell LRS-100-48
Support the project on Patreon


Comparison · Power supplies

HCA-100L or MeanWell LRS-100-48

Two models side by side: measurements taken by the author in their reviews, and their conclusions. The better value in each row is highlighted.

In brief: Based on review measurements: Test current: HCA-100L (8 A vs. 2.73); Temperature rise: MeanWell LRS-100-48 (70 °C vs. 112).

ModelHCA-100LHCA-100L2025Read review →MeanWell LRS-100-48MeanWell LRS-100-482020Read review →
Power, W100100
Test current, A82.73
Protection, A8.32.85
Temperature rise, °C11270
Review conclusionRecommendedRecommended

Only in one review: Current 8.3 A (HCA-100L); Ripple 80 mV (MeanWell LRS-100-48); Efficiency 91.5 % (MeanWell LRS-100-48); No load 0.2 W (MeanWell LRS-100-48).

HCA-100L: Much like its counterpart, it has high efficiency and stability, but practical sustained output is about 70–80 W.

MeanWell LRS-100-48: The PSU meets its stated specifications, works well, and the author unequivocally recommends it.

Figures were taken from the review text and checked against the quoted passages. Measurement conditions differ between reviews, so read the reviews yourself before buying. Prices at the time of review.

Compare two modelsor

Similar comparisons

← All: power supplies