/    Measurement database » Power supplies » HCF-100-12 or EPP-100-12
Support the project on Patreon


Comparison · Power supplies

HCF-100-12 or EPP-100-12

Two models side by side: measurements taken by the author in their reviews, and their conclusions. The better value in each row is highlighted.

In brief: Based on review measurements: Ripple: HCF-100-12 (30 mV vs. 175).

ModelHCF-100-12HCF-100-122026Read review →EPP-100-12EPP-100-12Mean Well · 2018Read review →
Voltage, V1212
Current, A8.36.3
Power, W100100
Ripple, mV30175
Review conclusionWith reservationsRecommended

Only in one review: Temperature rise 115 °C (HCF-100-12).

HCF-100-12: Ripple is 30 mV, but the transformer heats noticeably at rated load.

EPP-100-12: The PSU sustained up to 7.5 A without cooling, but had short ripple spikes up to 175 mV.

Figures were taken from the review text and checked against the quoted passages. Measurement conditions differ between reviews, so read the reviews yourself before buying. Prices at the time of review.

Compare two modelsor

Similar comparisons

← All: power supplies