/    Measurement database » Power supplies » QS-60-12 or HCF-60R
Support the project on Patreon


Comparison · Power supplies

QS-60-12 or HCF-60R

Two models side by side: measurements taken by the author in their reviews, and their conclusions. The better value in each row is highlighted.

In brief: Based on review measurements: Ripple: QS-60-12 (200 mV vs. 220); Efficiency: HCF-60R (91 % vs. 87); Temperature rise: QS-60-12 (108 °C vs. 111).

ModelQS-60-12QS-60-122026Read review →HCF-60RHCF-60R2025Read review →
Voltage, V1212
Current, A55
Power, W6060
Ripple, mV200220
Efficiency, %8791
Protection, A6.55.6
Temperature rise, °C108111
Review conclusionWith reservationsRecommended

Only in one review: Test current 6.5 A (QS-60-12); Under load 11.15 V (QS-60-12); No load 0.5 W (QS-60-12).

QS-60-12: Fairly decent, but in practice it is at most a 60 W unit, possibly around 50 W.

HCF-60R: A modern, capable design; the author recommends continuous loads of about 3.5–4 A.

Figures were taken from the review text and checked against the quoted passages. Measurement conditions differ between reviews, so read the reviews yourself before buying. Prices at the time of review.

Compare two modelsor

Similar comparisons

← All: power supplies