Two models side by side: measurements taken by the author in their reviews, and their conclusions. The better value in each row is highlighted.

In brief: Based on review measurements: Test current: 1205 (5 A vs. 4); Ripple: 1205 (300 mV vs. 350); Efficiency: 1205 (87 % vs. 86); No load: 1205 (0.35 W vs. 0.45); Temperature rise: 1204 (107 °C vs. 125).

Model120412042025Read review →120512052025Read review →
Current, A45
Test current, A45
Under load, V12.3312.04
Ripple, mV350300
Efficiency, %8687
No load, W0.450.35
Protection, A5.25.5
Temperature rise, °C107125
Review conclusionWith reservationsWith reservations

Only in one review: Voltage 12 V (1204).

1204: It regulates well but has elevated ripple; the author recommends about 3–3.5 A for continuous use.

1205: Its performance is close to the 1204, but it runs hot under load; continuous current should be no more than 4 A.