RS485 module with galvanic isolation for connecting RD60xx series power supplies
First, what is the RS485 interface? This type of connection is mainly used in industrial equipment. Its advantages include long communication distances, good noise immunity, and the ability to connect a large number of devices in parallel, so you don't need to run separate cables to the computer. For example, this type of connection is widely used at my workplace for turnstiles, thermal chambers, and even a DIY security system.
I don't know what packaging it usually comes in, since mine arrived in the box with the power supply.
Its dimensions are exactly the same as those of the WiFi module for RD series power supplies: 45x18.5 mm.

The first thing that stands out is the large number of protection components:
Two resettable fuses
Three TVS diodes
One spark gap
The module is built around the following chips:
RS485 transceiver — PL3085A
Two digital isolators — 122U31
Power is supplied by a galvanically isolated 5-to-5 V, 1 W converter.

There's also an image from the manufacturer, but for some reason it doesn't show all the components.

The module installs in the same slot as the WiFi module, so naturally you can only use one or the other.
For the connection and test, I used a piece of two-wire cable and a cheap USB-to-RS485 converter I bought locally.
The connection is very simple: the terminals are marked A and B, so just connect the matching terminals. There is no drain wire.
Select RS485 mode in the power supply settings. I didn't change anything else, but if you plan to connect several modules, you need to assign each one its own address in the system.

If you have more than one module, connect them in parallel in a daisy chain. Be careful: a star topology is very likely not to work. Also, as far as I know, there should be a terminating resistor at the end of the line, but there isn't one here.
The manufacturer states that up to 32 devices can operate on the network at the same time.

The only real design drawback is that the original enclosure has no external connectors for the communication line, so I had to test it with the case open.

There are also a few things to keep in mind when connecting it. For example, it says that when using RD6006 power supplies

At the same time, the product page has a video showing everything working quite smoothly with 24 devices connected.

The drivers you need depend on which converter you use for the connection. The important thing is that it provides a physical or virtual COM port.
I already had the drivers installed, and the software automatically detected that the converter was emulating COM6.
By the way, the seller wrote something about this board apparently working only with the RD6006, but I may have mistranslated his reply. In any case, the screenshot shows an RD6018-series converter connected.
In normal mode, operation is no different from connecting over USB, so there’s no point describing it.

But one of the key “features” of RS485 is that you can work with a large number of devices at once. For obvious reasons, I can’t demonstrate this in full, but I can at least show that the corresponding option is enabled here.
When you switch to it, a notification pops up. We confirm.

Start the search, and the software finds the converter and immediately shows its address in the system, model name, activity, modes, and serial number.

You can save the configuration. As far as I can tell, this is so you don’t have to search for devices every time.

Select the corresponding row and click Connect. The converter connects, and the current and voltage settings are displayed, along with the output current, voltage, and power. Unfortunately, functionality in this mode is severely limited, especially when it comes to displaying information, but to be fair, everything works.

While searching for devices on the network, the software “thinks” for a while, making it seem like it has frozen. I didn’t know that and started clicking different buttons, so in the end it told me off. The fact that it told me off is fine; what surprised me was that it did so in a language other than the usual English. I must have really annoyed it :)

To sum up, the module works without any problems. Everything installed and worked right away, which felt a little unusual. Basically, all I did was install the module, connect a couple of wires, plug in a USB converter, and launch the software. It found the port and connected to the converter on its own.
One advantage is the galvanic isolation, which improves reliability. They also didn’t skimp on protection, but there is one small caveat. The galvanic isolation here is not a safety barrier because the required clearances are missing. So if you just need to isolate one thing from another to reduce interference, ground loops, and so on, it’s great—but you mustn’t use it when there’s a large voltage difference.
That’s all. I hope you found this useful.
power managment softwsre freeware rs485, гальванической развязки интерфейсах rs-485, usb rs485 можно это подключить к телевизору через системный блок?, nlpd1 zy, преобразователь rs 485 usb свими руками с гальванической развязкой, гальваническая развязка 485, rs485 гальваническая развязка схема, опторазвязка 485, 122u31, модуль rs 031 подключение, гальваническая развязка микрофона, 2, rd60xx, pl3085a 122u31 rs485, rd60xx связь с компом, гальваническая развязка rs 485 купить, гальваническая развязка rs-485 купить, rs485 с гальванической развязкой ali, всё для rd60xx
Questions and answers
How do you connect the RS485 module to an RD6006 or RD6018 converter?
Install it in place of the WiFi module, connect terminals A and B to the matching terminals on a USB–RS485 converter, and select RS485 mode in the settings. For multiple devices, assign each a different address and wire them in parallel along a line, not in a star.
How many RD converters can an RS485 network support?
According to the manufacturer, up to 32 devices can work on the network at the same time. The article cites a stated operating cycle of 11 seconds when 32 devices are connected.
Does the RS485 module’s galvanic isolation protect against high voltage?
No. The author says the board lacks the required clearances to serve as a safety barrier. The isolation can reduce interference and ground loops, but should not be used where there is a large voltage difference.
The figures from this review are in the measurement database: Other devices
Discounted products
You may be interested in
Discounted products
All the content on the site and the advice are free, but we’d be grateful for your support of the project and the channel!
Comments1
Only registered readers can comment. It takes a minute to sign up, and you can log in with the same account you use on the forum.
Log inRegister


Comments are published in their original language.