/       /       /    LTO 18650 battery life test: 1500 mAh, 1200 cycles
Support the project on Patreon


LTO 18650 battery life test: 1500 mAh, 1200 cycles

Go to store
After reviewing the LTO batteries, I decided to run some life-cycle tests after all. I chose the second cell for the test because it looked noticeably better and had a capacity close to the claimed rating.
I tested it in several modes, but I’ll go through them in order.

The tests were run using the EBC-A10 load, which many of my readers will already know. As before, I set it up in a spot in the apartment where temperature fluctuations are minimal. It looked roughly like this (photo from another test).


I started with this mode:
5 A discharge down to 1.6 V
5-minute pause
3 A charge up to 2.8 V, cutoff at 100 mA
1-minute pause.

Each cycle ended up taking just under an hour.


But after 500 cycles, I got tired of watching the capacity decline so slowly. The results were more affected by temperature fluctuations than by aging, so I ran several tests in other modes. Differences from the previous test are shown in bold.

Cycles 501–800
7.5 A discharge down to 1.6 V
5-minute pause
4.5 A charge up to 2.8 V, cutoff at 100 mA
1-minute pause.

Cycles 801–1000
9 A discharge down to 1.6 V
5-minute pause
4.5 A charge up to 2.8 V, cutoff at 100 mA
1-minute pause.

Cycles 1001–1100
9 A discharge down to 1.6 V
Pause: 10 minutes
3 A charge up to 2.8 V, cutoff at 100 mA
1-minute pause.

Cycles 1101–1200
5 A discharge down to 1.6 V
Pause: 5 minutes
3 A charge up to 2.8 V, cutoff at 100 mA
1-minute pause.

As you might guess, I ran the tests in batches of 100 cycles, changing the settings in some cases. The graphs at the end of each stage looked something like this. Yes, I calibrated the load before the tests, but I made a mistake here: I checked the calibration only for discharge and forgot about charging. So don’t be surprised that charging put slightly less energy in than the discharge took out. It doesn’t matter in this case.


I compiled all the results into a single file as I went, which let me plot the graph below.
Every 100 cycles, I removed the battery from the holder and measured its impedance. Usually everything went smoothly, but for some reason there was a sudden jump in capacity at cycles 900 and 1000. I can sort of explain the jump at 1000: the test mode changed, and the pause ended up being a little longer. But I don’t know what caused it at 900.



The same graph, with the energy output measurements in mWh added.


Meanwhile, the battery’s impedance kept rising, slowly but steadily. Below are the results after each 100-cycle batch: 1200 cycles, 12 measurements.


There was a reason for testing in different modes: it let me draw a few conclusions.
1. In charge/discharge mode at 3/4.5 A, capacity declines very slowly. Over 500 cycles, it dropped by about 1.5%. Extrapolating to 80% capacity gives roughly 6500 cycles.
2. In 4.5/7.5 A mode, capacity started dropping much faster, falling by about 4.5% over 300 cycles. At this rate, the battery will last no more than 1200 cycles.
3. If you raise the discharge current to 9 A (6C), the results will be even worse. I doubt it would last more than 700–800 cycles.
4. Reducing the charge current to 3 A and increasing the pause after discharge from 5 to 10 minutes made virtually no difference. That means discharge current affects cycle life more than charge current does.
5. Switching back to the first mode, 3/5 A, made the graph smoother again, though not as smooth as it was at the very beginning. The battery has worn down, and its impedance has increased.

In my opinion, the battery delivered pretty good cycle-life results. A 3 A (2C) charge current and 5 A (over 3C) discharge current seem optimal for it. I think the discharge current could be raised further, to 6 A (4C), for example, but at 7.5 A (5C), cycle life will be significantly reduced.

In short, the life-cycle test showed that the LTO battery is quite durable, although the batteries themselves are low quality and have widely varying characteristics.
Go to store
This page was found when searching for:
ресурсные испытания литиевых аккумуляторов, проверка lto аккумуляторов, lto кривая  заряда, https://www.kirich.blog/obzory/akkumulyatory/990-resursnyy-test-lto-akkumulyatora-18650-emkostyu-1500mach-1200-ciklov, аккумуляторы ресурсные, lto 18650 обзоры, lto 23680 тест, тест lto аккумуляторов, старение lto аккумулятора, lto аккумуляторы тестирование на морозе, онлайн тест lto аккумуляторов, аккумуляторы lto испытания япония

Questions and answers

What capacity did the LTO 18650 cell have after 1200 cycles?

The article includes capacity graphs for the test stages, but does not state the final capacity after 1200 cycles in the text.

How did discharge current affect the LTO cell’s cycle life?

At 7.5 A discharge, capacity fell by about 4.5% in 300 cycles; at 9 A, the author estimates no more than 700–800 cycles. Capacity declined more slowly at 5 A.

Which operating currents does the author recommend for this LTO cell?

The author considers 3 A charge and 5 A discharge optimal. Reducing charge current and extending the post-discharge pause had little effect on cycle life; discharge current mattered more.

The figures from this review are in the measurement database: Batteries

Calculate manuallyAll calculators

Discounted products


You may be interested in


Discounted products


Support the project

All the content on the site and the advice are free, but we’d be grateful for your support of the project and the channel!

Comments1

Comments are published in their original language.