Fuses for a multimeter, 1 and 10 amps
$7.51
Of course, there are plenty of nuances here, and I’ll try to explain some of them.
As a reminder, to keep up with new topics on the blog, I recommend following me on Instagram, where I’ll post notifications about all new topics and maybe write about something interesting too - link to my account
You can also subscribe to updates and new articles on the Telegram channel - https://t.me/KirichBlog
These fuses were intended for my Uni-t UT-181A multimeter.
I’ll start with a bit of history. Almost as soon as electric current came into use, people had to find a way to protect electrical circuits from overloads and short circuits. For many years, nothing better than a simple piece of wire was invented. Of course, it was made much more simply than it is today (where are those PUE experts when you need them?).

That piece of wire, albeit in a somewhat different form, continued to be used later on, but in a safer design. What’s more, as far as I know, the USSR produced kits containing automotive fuses and calibrated fuse wire. So you didn’t have to run to the store to replace a fuse; you could simply replace the wire. Unfortunately, I couldn’t find a photo, but here’s one of mains fuses of a similar design.

Before moving on to more modern protective devices, it’s worth explaining why we need fuses at all.
They’re needed in two main situations:
1. To protect the wiring. In this case, the fuse really does blow only after your device has failed. For example, a fuse at the input of a power supply is usually there to protect the wiring and the device from catching fire.
2. To protect the device itself. For example, in a multimeter, the fuse blows if the user makes a mistake or the current exceeds the limit. Another example is a fuse placed before a varistor in a power supply: if the voltage gets too high, the varistor blows first and shorts the circuit, then the fuse blows and disconnects the device from the mains, while the device itself often remains intact.
As we can see, the saying “the fuse blows last” is half true; in some situations, that’s exactly what happens.
Now for the modern era.
There’s an enormous range of fuses available today: blade, round, cartridge, leadless, resettable, high-voltage, fast-acting, slow-blow, and many, many more.

But the classic glass cartridge fuses are still around, and even these come with plenty of nuances.
First, they differ in rated voltage, most commonly 250 V, as well as in size. The most common sizes are 5×20 mm and 6.3×32 mm.

Fuses are also rated by their operating speed:
FF: Ultra-fast (very quick acting, ultra-rapid)—for protecting semiconductor devices
F: Fast-acting, or standard (quick-acting, fast, standard).
M: With a short time delay (medium time lag).
T: Time-delay (time-lag).
TT: With a long time delay (super time-lag).
Fast-acting fuses usually have a small drop of solder on the wire. When heated, it melts and spreads along the wire, partially dissolving it in the process and speeding up the fuse blowing.

Slow-blow fuses work the other way around: the goal is to increase thermal inertia so the wire only trips after heating up for a while.
To do this, the wire may be wound around a nonflammable core. Another example is a spring with a drop of solder and a heater: when the current exceeds the limit, the heater warms up and melts the solder, and only then does the spring break the circuit.

The biggest problem is the arc that forms when a fuse blows. That’s why fuses are also rated for two more parameters:
1. Rated voltage
2. Breaking capacity.
The rated voltage and fuse size are usually closely related. That’s why I personally don’t like it when power supplies use compact fuses instead of the familiar 5×20 mm ones.
The same goes for breaking capacity, especially when it comes to power wiring and, in particular, industrial applications. The higher the breaking capacity, the stronger the arc while the circuit is being interrupted. To protect against this, a ceramic body is used instead of a glass one: it’s simply stronger and can withstand higher temperatures. The fuse may also be filled with quartz sand, and the fuse wire can be made thinner in several places so that, if an arc occurs, it blows at several points at once.
There are also high-voltage fuses, such as the one in your microwave. In this case, a spring is used to increase the gap as quickly as possible.

Very compact fuses are now widely used. They have a significant advantage: because the fuse has a low overall mass, it takes relatively little energy to blow it, so it can have very low parasitic resistance. I recently wrote several articles about low-voltage UPSs, where I mentioned that I use these very fuses. They have lower losses than ordinary cartridge fuses.
Incidentally, mains fuses are also made in this type of package, though the price is not exactly appealing.
Also, small fuses must not be used with DC if the circuit voltage is above 27-30 V and there are no additional limiters.

Fuses may also have additional markings consisting of two letters. Let’s see what they mean.
The first letter:
g — blows when any overcurrent occurs,
a — blows only at a high overcurrent (i.e. only in the event of a short circuit, not an overload).
The second letter indicates the application category, which takes into account the required operating speed:
G— (General purpose) General-purpose, standard speed.
R— (Rectifiers), sometimes S (Semiconductor), for use with semiconductor switches; very fast.
M— (Motor) For use with motors; slow.
PV— (Photovoltaic) — for solar batteries.
N— Contact-compatible with fuses used in North America under the UL 248 standard.
D - Contact-compatible with the time-delay motor fuses used in North America under UL 248.
On one of the websites I found a very simple, accessible explanation of the main types—translated by Google.
• Class aR fuses
Class aR fuses provide only partial breaking capacity (short-circuit protection only) for protecting power semiconductors (IEC utilization category). Note: aR fuses are often faster (with a lower I²t value) than comparable gS or gR fuses. A class aR fuse cannot be used in place of a class gR fuse.
• Class gR fuses
Class gR fuses provide full breaking capacity (overload and short-circuit protection) for protecting semiconductors, cables, and all of the installation’s distribution equipment. Designers can often replace a class aR fuse with a class gR fuse.
• Class gS fuses
Class gS fuses are very similar to class gR fuses. Both provide full-range breaking capacity (overload and short-circuit protection), but class gS fuses have lower power dissipation than class gR fuses because of their narrower gate-melting values. This also means that class gS fuses have a lower fuse-body temperature.
Differences between class aR and class gR/gS fuses
Class aR fuses have a high minimum breaking current relative to their rated current. The main time-current characteristic of class aR fuses is the CC curve; another protective device must be installed above it.
Class gR fuses offer significantly improved semiconductor protection. They should be used in low-voltage equipment designs and to protect power electronics equipment.
I’ll come back to these markings later. The graph makes the differences easier to understand: an aR fuse can carry a high current for quite a long time, but in the event of a short circuit it should blow as quickly as possible. A gR fuse, on the other hand, should blow when the current exceeds its rating by a relatively small amount.
As you can see, we’ve come a long way from the familiar “bit of wire” rated for a certain current. It’s all much more complicated than simply blowing when the current is exceeded.

Now we can move on to the review itself.
As often happens in amateur radio, I blew the fuse in my multimeter. Actually, I first blew the one for the lower range, but I’ll talk about that later. More recently, I also blew the fuse for the higher range when I forgot to switch the meter from current to voltage measurement and touched the output terminals of the UPS I wrote about recently with the probes.
Yes, this is probably the most common reason for blowing a multimeter fuse: switching back and forth between measuring current and voltage.
There’s nothing for it but to buy a new one, and there are several options:
1. Buy the same type that was originally installed.
2. Looking for an equivalent
3. Looking for an equivalent of an equivalent—in plain English, buying a counterfeit.
At first I wanted to go with option two, but it turned out that it often slides seamlessly into option three. So I decided not to cut corners and went with option one: buying an original fuse.
To do that, I went to the Uni-T store on AliExpress and checked the prices. As often happens, my option turned out to be not only the most expensive, but also the only one with paid shipping. In the end, the fuses (2 pieces) cost $7.51, plus $0.99 for shipping, for a total of $8.50.
Yes, a plain Chinese fuse cost me $4.25 per piece, roughly the price of a cheap multimeter. But that’s still not all that expensive compared with products from more premium brands.

The range of fuses is actually quite large and, as I understand it, covers the full range of instruments they make. The fuses are sold in pairs, but not one small and one large—two of the same type.
By the way, I was once surprised to see the familiar word “Porcelain” in a product listing. No, it’s correct: the Ukrainian word “porcelain” means porcelain, essentially ceramic—in this case, the material the fuse body is made of.

I should mention that shipping was fast, which is great, since I need the instrument for work all the time. I placed the order on April 14, and on the 28th—exactly two weeks later—I picked up the envelope from a Nova Poshta parcel locker.

The package included a small slip with my details, as well as the fuse and multimeter models the fuses were intended for.

The packaging was as simple as it gets. As stated, they sent two fuses of the same type.
They’re really quite large—certainly for a multimeter—just a little shorter than a standard AAA battery. In the fourth photo, it’s shown next to the multimeter’s other type of fuse and a 10 A fuse for the old-style domestic screw-in fuses (does anyone still remember those?).

I didn’t look for the datasheet specifically, but I found these fuses on the manufacturer’s website, and they’re classified as industrial grade.

There’s also a datasheet there, which includes, among other things, a graph of trip time versus current. Incidentally, I don’t see the characteristic plateau for the aR series on it.

There’s also a table showing the trip time. For my 10 A fuse, a fourfold overload should make it trip somewhere between 10 ms and... 1 s. That’s quite a range, though.

1, 2. Appearance and markings. It clearly states that the fuse is rated for voltages up to 1000 V, for both AC and DC, which is extremely important. The maximum breaking capacity is also listed: 50 kA AC and 30 kA DC.
3, 4. Here’s the new fuse next to the old one. They look almost identical; the old one’s printing is slightly bolder.

Switching, and especially protecting DC lines, is a major challenge—for example, in solar power systems. As I’ve written before, an arc on DC doesn’t extinguish on its own, because unlike AC, the current flows continuously and doesn’t cross zero.
Special fuses and circuit breakers designed specifically for DC are used for these applications. DC breakers even have polarity.

The difference from a regular circuit breaker is fairly small: a magnet is added to pull the arc toward the arc chute.
1 — moving contact
2 — fixed contact
3 — silver-alloy contact tip
4 — magnet
5 — arc chute
6 — bracket

The magnet has two poles, so polarity matters. That’s why two single-pole breakers aren’t equivalent to one double-pole breaker, where the magnets in the two halves are oriented differently.
By the way, I have an article where I also explained what can happen when you switch DC above 30 V using switching mechanisms not designed for it.

They seem to weigh exactly the same to me; a difference of 0.07 g is negligible. The new one is on the left again, the old one on the right. Maybe the old one let out some magic smoke, which is why it weighs less :)

For objective reasons, I can't measure the resistance of the old fuse (by the way, could someone measure the resistance of the fuses in their 181A?), so I'll measure the two that were sent to me.
As far as I'm concerned, repeatability looks fine too.
Ideally, of course, I should measure the characteristics of the fuses I received somehow, but these experiments would be rather expensive, and I only have two fuses.

I bought the second type of fuse quite a while ago. At first I also wanted to buy the originals, but honestly, I couldn't bring myself to spend what the Uni-t store was asking ($3.75 for 2). So I ordered an equivalent, in this case, Siba.
They also have a fairly wide range, but as you may have guessed, the ones I needed turned out to be the most expensive, and a pack of ten came to almost $11—or, to be exact, $10.7 including shipping. Actually, all the other ones cost $11.7, except for the 500 mA version.

This fuse has blown on me at least twice, maybe even three times. The first time was when I tried to measure the no-load current of a regular transformer—not a particularly powerful one, either—and there was a current surge from remagnetization.
The second time, I accidentally started switching operating modes while charging the multimeter's battery.
I don't remember the third time, but the second and third times it was the little wire link that blew, because I had to get on with the job and had no spare fuses.
There were no 800 mA fuses available, so I had to buy a 1 A one.

Judging by its appearance and price, this does look more like an original. I could have bought them offline, of course (unlike the previous ones, these are much easier to find), but they cost around $3–4 each there.

I couldn't find an individual datasheet, but these fuses are listed in the company's general catalog of miniature and SMD fuses.
The two key parameters for me here were the specified operation at DC—rated at 1000 V—and the speed: it has to be very fast.

There are also limits on the trip time depending on how much the current is exceeded.

Subjectively, the markings look genuine, though what are markings, really? Just letters and numbers printed on a special machine.

1, 2. The original fuse had no markings on the body at all; only the ends indicated that it was FF, i.e. very fast, and rated for 800 mA.
3, 4. The new one compared with the old one.

The weight, however, is significantly different: the Siba is one and a half times lighter. So there are two possibilities: either the ceramic is thinner, or they "forgot" to add the sand.

The resistance measurements are also rather ambiguous. The thing is, the specified voltage drop for these fuses is 0.75 V, which apparently means the drop at rated current. That would make the resistance about 0.75 Ω, but in reality it's three times lower, which isn't really a good thing.
I checked four samples at random, and the resistance was more or less the same in all of them.

Mostly out of curiosity, I took the old fuses apart.
The larger one's construction is interesting in its own way. First, the ceramic body is very thick. It also has contacts at the ends, with caps fitted over them, while the fuse wire itself has a complex shape and is welded to the end contacts.
There's also some kind of dark bump on the inside of the end cap. I thought it might be magnetic, but no—it's just a bump.

I weighed the body and the sand inside. There was almost 1 gram of sand; I think that, accounting for what stuck to the wire, it would come to exactly 1 gram.

The second fuse is somewhat simpler. It also had sand inside, but I couldn't see the wire; apparently it burned away in the process. The sand had actually fused together, so I had to dig it out with a small screwdriver.
The ends have a distinctive shape. I wonder if they all look like this.
I weighed the sand. There was noticeably less of it here, so the theory that Siba doesn't use sand doesn't hold up. Perhaps the casing itself is thinner.

The sand is different: the 10 A fuse has lighter-colored sand, while the smaller fuse's sand has a faint but distinctive chemical smell.
I really want to open up a new Siba fuse. I could easily sacrifice one, but simply cutting it open isn't very interesting. I'd like to check its specifications first, and doing that properly is a bit more involved than just opening it up. So for now I'm thinking about the best way to test it. Maybe someone can suggest something.

A few words about Uni-t's technical support and service for measuring instruments.
When the 800 mA fuse last blew—or rather, not the fuse but the jumper, a thin wire—I burned out the current-measuring shunt on the 600 mA range. In the photo, these are resistors R43 and R44, rated at 1 Ω each.
Yes, I know, I was an idiot :( But I had to do something, so I replaced them with 1206 resistors, also 1 Ω, with 1% tolerance.
To reduce the effect of the TCR, I used eight resistors instead of two, in a 2S4P configuration. That gave me the same 0.5 Ω total resistance, but with higher power handling and therefore less heat. The actual resistance came out slightly higher than needed, so I adjusted it by selecting a high-value resistor to put in parallel with the whole assembly. I checked it using another instrument that had been verified earlier, so I knew exactly what reading to expect.
By the way, about TCR and resistor accuracy. A common misconception is that you can use an accurate instrument to simply select resistors with the right nominal value from a batch of ordinary 5% parts. No, it doesn't work that way. When the temperature changes, you can throw all your measurements out the window, because precision resistors are accurate not only in their nominal value—they also have a much lower TCR, i.e. less resistance variation with temperature!
But I digress.
Of course, I wasn't too happy with this situation, so I messaged the service center and asked about two things:
1. A firmware update, since I have the very first version
2. Buying replacement resistors for the current-measuring shunt.
No luck on either count: they don't have the firmware or the resistors... And when I continued the conversation, it turned out they knew my review of this multimeter very well. That's nice on the one hand, but disappointing on the other, because this was the only place where I hoped to get help.
If anyone knows where to buy the original resistors, please let me know. I'd really appreciate it. Or what do you think—is it worth just leaving the 1206 1% resistors I installed?

The conclusions aren't entirely clear-cut.
I have no questions about the 10 A fuses. There's a good chance they're genuine: the place I bought them, their appearance, the price, and even a simple weighing all point that way.
The 1 A fuses are less straightforward. Subjectively, they look genuine, but objectively there's a discrepancy: I don't know their weight, and their resistance is three times the value stated in the datasheet. If I get the chance and come up with a simple test method, I'll check whether they meet the stated specifications and open one up.
That's all for now. May your fuses blow less often. I'd also be very glad to hear your comments and recommendations, see your links, and learn about your experience.
$7.51
This page was found when searching for:
где стоит предохранитель на мультиметре актаком, 11, предохранитель в мультиметр с какой характеристикой, предохранители на мультиметр, какой предохранители стоят в мультиметре, какой предохранитель стоит в тестере, какая характеристика предохранителя для амперметра тестера, предохранитель для стабилизатора напряжения 10 ампер подходит ли, предохранитель для тестера особенности, разница сопротивление предохранителей 1а и 10а, сопротивление предохранителей 1а и 10а, разница сопротивление предохранителей 1 а и 10 а, на сколько отличается сопротивление предохранителей 1 а и 10 а, капелька припоя на проводке в предохранителе зачем, предохранитель в амперметре китай замена фото, предохранитель в мультиметре, какие бывают предохранители для мультиметра 10а, мультиметр какой мощности стоит предохранитель по току, можно ли использовать предохранитель на 10 а для защиты электрической цепи от замыкания, при каком токе перегорает автомобильный предохранитель на 10а, предохранитель в мультиметр какой нужен, в мультиметре дт-838 перегорел d-1a что это,и чем заменить, сколько ампер ставится предохранитель на мультиметре дт-838, какие предохранители нужны для мультиметра, https://www.kirich.blog/stati/informaciya-dlya-nachinayuschih/1153-predohraniteli-dlya-multimetra-1-i-10-amper
где стоит предохранитель на мультиметре актаком, 11, предохранитель в мультиметр с какой характеристикой, предохранители на мультиметр, какой предохранители стоят в мультиметре, какой предохранитель стоит в тестере, какая характеристика предохранителя для амперметра тестера, предохранитель для стабилизатора напряжения 10 ампер подходит ли, предохранитель для тестера особенности, разница сопротивление предохранителей 1а и 10а, сопротивление предохранителей 1а и 10а, разница сопротивление предохранителей 1 а и 10 а, на сколько отличается сопротивление предохранителей 1 а и 10 а, капелька припоя на проводке в предохранителе зачем, предохранитель в амперметре китай замена фото, предохранитель в мультиметре, какие бывают предохранители для мультиметра 10а, мультиметр какой мощности стоит предохранитель по току, можно ли использовать предохранитель на 10 а для защиты электрической цепи от замыкания, при каком токе перегорает автомобильный предохранитель на 10а, предохранитель в мультиметр какой нужен, в мультиметре дт-838 перегорел d-1a что это,и чем заменить, сколько ампер ставится предохранитель на мультиметре дт-838, какие предохранители нужны для мультиметра, https://www.kirich.blog/stati/informaciya-dlya-nachinayuschih/1153-predohraniteli-dlya-multimetra-1-i-10-amper
Questions and answers
Which fuses are for the Uni-t UT-181A multimeter?
The author examines 1 A and 10 A fuses intended for the Uni-t UT-181A.
Are the 1 A and 10 A fuses for the Uni-t UT-181A genuine?
The author considers the 10 A fuse genuine based on where it was bought, its appearance, and its measured weight. The 1 A fuse’s resistance is three times the datasheet value, and the author has not yet confirmed its specifications.
Why does a multimeter need a fuse?
It protects the meter if the user makes a mistake or the current exceeds the permitted level.
The figures from this review are in the measurement database: Other devices
Calculate manuallyAll calculators
Discounted products
You may be interested in
Discounted products
Support the project
All the content on the site and the advice are free, but we’d be grateful for your support of the project and the channel!
Comments4
Discuss on the forumHave a question or some experience to share? Discuss the article with the author and readers: the forum is a convenient place to share schematics and photos.
Go to the forumOnly registered readers can comment. It takes a minute to sign up, and you can log in with the same account you use on the forum.
Log inRegister




Comments are published in their original language.