/    Measurement database » Power supplies » HCA-60 or HCF-60R
Support the project on Patreon


Comparison · Power supplies

HCA-60 or HCF-60R

Two models side by side: measurements taken by the author in their reviews, and their conclusions. The better value in each row is highlighted.

In brief: Based on review measurements: Ripple: HCF-60R (220 mV vs. 700); Efficiency: HCF-60R (91 % vs. 84.5); Temperature rise: HCF-60R (111 °C vs. 115).

ModelHCA-60HCA-602025Read review →HCF-60RHCF-60R2025Read review →
Current, A55
Power, W6060
Ripple, mV700220
Efficiency, %84.591
Protection, A5.45.6
Temperature rise, °C115111
Review conclusionWith reservationsRecommended

Only in one review: Voltage 12 V (HCF-60R); Test current 5 A (HCA-60).

HCA-60: Ripple is high, but temperatures are better than on the HCA-48; the author puts its practical output at about 50 W.

HCF-60R: A modern, capable design; the author recommends continuous loads of about 3.5–4 A.

Figures were taken from the review text and checked against the quoted passages. Measurement conditions differ between reviews, so read the reviews yourself before buying. Prices at the time of review.

Compare two modelsor

Similar comparisons

← All: power supplies