/    Measurement database » Power supplies » HCF-60L or HCF-60R
Support the project on Patreon


Comparison · Power supplies

HCF-60L or HCF-60R

Two models side by side: measurements taken by the author in their reviews, and their conclusions. The better value in each row is highlighted.

In brief: Based on review measurements: Ripple: HCF-60R (220 mV vs. 400); Efficiency: HCF-60R (91 % vs. 83.5); Temperature rise: HCF-60L (105 °C vs. 111).

ModelHCF-60LHCF-60L2025Read review →HCF-60RHCF-60R2025Read review →
Current, A55
Power, W6060
Ripple, mV400220
Efficiency, %83.591
Protection, A5.65.6
Temperature rise, °C105111
Review conclusionNot recommendedRecommended

Only in one review: Voltage 12 V (HCF-60R); Test current 5.6 A (HCF-60L); No load 0.3 W (HCF-60L).

HCF-60L: It generates substantial interference and sustains no more than 45–50 W; the author advises against it.

HCF-60R: A modern, capable design; the author recommends continuous loads of about 3.5–4 A.

Figures were taken from the review text and checked against the quoted passages. Measurement conditions differ between reviews, so read the reviews yourself before buying. Prices at the time of review.